MODEL:SKD-60 Dual Output Switching Power Supply |
|
Features: High efficiency,high reliability Universal AC input /full range 100% full load burn-in test Protection: Short circuit/Over load/Over voltage LED indicator for power on Cooling by free air convection Fixed switching frequency at 54KHz 1 year warranty Dimensions: 159*97*38mm(L*W*H) |

casing No. : H003 | |
|
MODEL |
SKD-60A |
SKD-60B |
|
CH1 |
CH2 |
CH1 |
CH2 |
|
OUTPUT |
DC Voltage |
5V |
12V |
5V |
24V |
|
Voltage Tolerance |
¡À2% |
¡À6% |
¡À2% |
¡À5% |
|
Rated Current |
4A |
3A |
3A |
1.8A |
|
Current Range |
0.3-6A |
0.2-4A |
0.3-6A |
0.2-2.2A |
|
Rated Power |
56W |
58W |
|
Ripple & Noise |
75mVp-p |
150mVp-p |
75mVp-p |
150mVp-p |
|
DC Adjustment Range |
CH1£º -5%£¬+10% |
CH1£º -5%£¬+10% |
|
Setup, Rise, Hold Time |
300ms,50ms ,80ms/230VAC 800ms,50ms,10ms/115VAC at full load |
|
INPUT |
Voltage Range |
85¡«264 VAC/ 47¡«63 Hz£» 120¡«370VDC |
|
AC Current |
2A/115 V 1A/ 230 V |
|
Efficiency |
73% |
76% |
|
Inrush Current |
Cold start 30A/115VAC 60A/230VAC |
|
Leakage Current |
£¼3.5mA/240VAC |
|
PROTECTION |
Over Load |
105%¡«150% |
|
Protection: Shut down o/p voltage, re-power on to recover |
|
Over Voltage |
115%~135% |
|
Protection: Hiccup mode, recovers automatically after fault condition is removed |
|
ENVIRONMENT |
Working Temp., Humidity |
-10¡æ¡«+60¡æ; 20%¡«90 %RH |
|
Storage Temp., Humidity |
-20¡æ¡«+85¡æ; 10%¡«95 %RH |
|
Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
|
STANDARD |
Safety Standard |
Design refer to UL1012 , UL60950 ,EN60950 |
|
EMC Standard |
Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 |
|
OTHERS |
Weight |
0.54Kg |
|
Packing |
30pcs/16.7Kg/0.99CUFT |
|
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
.4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
|

|