MODEL:HPSP-500 With PFC and Parallel Function Switching Power Supply |
|
Features: ¡¤ High efficiency, high reliability
¡¤Universal AC input/ full range
¡¤Built-in active PFC function, PF>0.95
¡¤Protections: Short circuit/ Over load/ Over voltage/ Over temperature
¡¤Forced air cooling by built-in DC fan
¡¤Current sharing up to 2000W(3+1)
¡¤With power good and fail signal output
¡¤Built-in remote ON-OFF control and remote sense function
¡¤1 year warranty
¡¤Dimensions: 278*127*63.5mm(L*W*H) |

casing No. : H025 | |
|
|
HPSP-500 -5 |
HPSP-500-12 |
HPSP-500-13.5 |
HPSP-500 -15 |
HPSP-500 -24 |
HPSP-500 -27 |
HPSP-500 -48 |
|
|
|
|
|
|
|
|
|
|
|
|
¡À2.0% |
¡À1.0% |
¡À1.0% |
|
¡À1.0% |
¡À1.0% |
¡À1.0% |
|
|
80A |
41.5A |
37A |
|
|
|
|
|
|
0-80A |
0-41.5A |
0-37A |
|
|
|
|
|
|
400W |
498W |
499.5W |
495W |
499.2W |
499.5W |
504W |
|
|
|
|
|
|
|
|
|
|
|
-5%,+10% |
-17%,+10% |
¡À11% |
-10%,+20% |
-17%,+10% |
¡À11% |
-15%,+17% |
|
|
1500ms,50ms,15ms at full load |
|
|
|
90¡«264 VAC 47-63Hz£»127¡«370VDC |
|
|
0.95/230VAC 0.98/100VAC at full load |
|
|
|
|
|
76% |
82% |
82% |
82% |
84% |
84% |
86% |
|
|
Cold start 20A/115VAC 40A/230VAC |
|
|
|
|
|
|
|
Protection: Constant current limiting, recovers automatically after fault condition is removed
|
|
|
115%¡«135% |
|
Protection type: Shut down o/p voltage, re-power on to recover |
|
|
RTH2¡Ý95¡æ (Detect on heatsink of Q1,Q7 power transistor & L3 output choke )
|
Protection type: Shut down o/p voltage, re-power on to recover
|
|
|
|
RC+/RC£:4 ~ 10VDC Power off, <0 ~ 0.8VDC Power on
|
|
|
|
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
|
|
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
|
|
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
|
|
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
|
|
|
Design refer to UL1950,TUV EN60950 |
|
|
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
|
|
|
|
|
|
|
|
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |

 |