MODEL:HPSP-1500 With PFC and Parallel Function Switching Power Supply |
|
Features: ¡¤ High efficiency, high reliability
¡¤ AC input inrush current limiting
¡¤ Built-in active PFC function, PF>0.95
¡¤ Protections: Short circuit/ Over load/ Over voltage/ Over temperature
¡¤ Built-in constant current limiting circuit
¡¤ Built-in remote ON-OFF control and remote sense function
¡¤ 3 years warranty
¡¤ Dimensions: 278*129*190.5mm£¨L*W*H£© |

casing No. : H026 | |
|
|
HPSP-500-5 |
HPSP-500-12 |
HPSP-500-13.5 |
HPSP-500-15 |
HPSP-500-24 |
HPSP-500-27 |
HPSP-500-48 |
|
|
|
|
|
|
|
|
|
|
|
|
¡À6.0% |
¡À3.0% |
¡À2.0% |
|
¡À1.0% |
¡À1.0% |
¡À1.0% |
|
|
217.5A |
112.5A |
100.5A |
|
|
|
|
|
|
0-217.5A |
0-112.5A |
0-100.5A |
|
|
|
|
|
|
1087.5W |
1350W |
1356.75W |
1350W |
1353.6W |
1360.8W |
1368W |
|
|
1200W |
1500W |
1500W |
1500W |
1500W |
1500W |
1500W |
|
|
|
|
|
|
|
|
|
|
|
-5%,+10% |
-17%,+10% |
¡À11% |
-10%,+20% |
-17%,+10% |
¡À11% |
-15%,+17% |
|
|
1.5s,50ms,15ms/230VAC at full load |
|
|
|
176¡«264 VAC 47-63Hz£»248¡«370VDC |
|
|
PF>0.95/230VAC at full load |
|
|
|
|
|
77% |
84% |
84% |
84% |
85% |
85% |
86% |
|
|
|
|
|
|
|
|
|
|
Protection: Constant current limiting, recovers automatically after fault condition is removed |
|
|
115%¡«135% |
|
Protection type: Shut down o/p voltage, re-power on to recover |
|
|
95 (TSW1) Detect on the heatsink of PFC MOSFET 90 (TSW2) Detect the winding of output choke |
Protection:Shut down o/p voltage, recovers automatically after temperature goes down |
|
|
|
RC+/RC-£º0~0.8V Power on, 4~10V Power off, sink current <30mA
|
|
|
|
-10¡æ¡«+65¡æ£»20%¡«90 %RH |
|
|
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
|
|
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
|
|
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|
|
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
|
|
|
Design refer to UL1950,TUV EN60950 |
|
|
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
|
|
|
|
|
|
|
|
|
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power.
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
 |