MODEL:HDR-120 Single Output Industrial DIN Rail Power Supply |
Features:
¡¤ Universal AC input / full range
¡¤Protections: Short circuit/ Over load/ Over voltage/ Over temperature
¡¤Cooling by free air convection
¡¤Can be installed on DIN rail TS-35/7.5 or 15
¡¤LED indicator for power on
¡¤100% full load burn-in test
¡¤Fixed switch frequency at 55KHz
¡¤1 year warranty
¡¤Dimensions: 65.5*125.2*100mm (W*H*D) |

casing No. : H036 |
|
|
MODEL |
HDR-120-12 |
HDR-120-24 |
HDR-120-48 |
|
OUTPUT |
DC Voltage |
12V |
24V |
48V |
|
Voltage Tolerance |
¡À2% |
¡À1% |
¡À1% |
|
Rated Current |
10A |
5A |
2.5A |
|
Current Range |
0-10A |
0-5A |
0-2.5A |
|
Rated Power |
120W |
120W |
120W |
|
Ripple & Noise |
80mVp-p |
80mVp-p |
100mVp-p |
|
DC Adjustment Range |
12-14V |
24-28V |
48-53V |
|
Setup, Rise Time |
500ms,70ms/230VAC at full load500ms,70ms/115VAC at full load |
|
Hold Time |
36ms/230VAC32ms/115VAC at full load |
|
INPUT |
Voltage Range |
88¡«132 VAC/176~264VAC47¡«63 Hz£»selected by 248¡«370VDC |
|
AC Current |
2.6 A/115 V 1.6A/ 230 V |
|
Efficiency |
80% |
84% |
85% |
|
Inrush Current |
Cold start 20A/115V 40A/230V |
|
Leakage Current |
£¼3.5mA/240VAC |
|
PROTECTION |
Over Load |
105%¡«150% |
|
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|
Over Voltage |
120%~135% |
|
Protection type: Shut down o/p voltage, re-power on to recover |
|
Over Temp |
85¡æ¡À5¡æ(TSW1) |
90¡æ¡À5¡æ(TSW1) |
90¡æ¡À5¡æ(TSW1) |
|
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
|
ENVIRONMENT |
Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
|
Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
|
Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|
SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
|
STANDARD |
Safety Standard |
Design refer to UL508,UL60950-1£¬TUV EN60950-1 |
|
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) |
|
OTHERS |
Weight |
0.79Kg |
|
Packing |
20pcs/16.5Kg/1.1CUFT |
|
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |