| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
85¡«264 VAC47¡«63 Hz£»120¡«370VDC |
| AC Current |
1.2A/115 V 0.6A/ 230 V |
| Efficiency |
72%/115VAC(SKS-40-5); 76%/115VAC(SKS-40-12); 76%/115VAC(SKS-40-15); 78%/115VAC(SKS-40-24); |
| Inrush Current |
Cold start 30A/115VAC 60A/230VAC |
| Leakage Current |
£¼1 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
110%¡«160% |
| |
Protection type: Fold back current limiting, auto-recovery |
| Over Voltage |
115%¡«135% |
| |
Protection type: hiccup mode, auto-recovery |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL1012, UL1950£¬TUVEN60950 |
| EMC Standard |
Design refer to EN55022£¬EN61000-3-2£¬-3£¬EN61000-4-2£¬3£¬4£¬5£¬ENV50204£¬EN55024 |
| |
|
| OTHERS |
|
| Weight |
0.44Kg |
| Packing |
30pcs/13.9Kg/0.86CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives.
|
| |
|
| OUTPUT |
|