| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
85¡«132 VAC/180¡«264VAC 47¡«63 Hz£»selected by switch 255¡«370VDC |
| AC Current |
2.4A/115 V 1.2A/ 230 V |
| Efficiency |
70%(SKS-100-3); 78%(SKS-100-5); 80%(SKS-100-7.5); 81%(SKS-100-12); 81%(SKS-100-15);
82%(SKS-100-18); 84%(SKS-100-24); 84%(SKS-100-27); 84%(SKS-100-48); |
| Inrush Current |
Cold start 30A/115V 60A/230V |
| Leakage Current |
£¼1 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
135%¡«165% |
| |
Protection type: Shut down o/p voltage, recovers automatically after fault
condition is removed. |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P£º1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL1012 |
| EMC Standard |
Design refer to FCC Part15 J Conduction Class B |
| |
|
| OTHERS |
|
| Weight |
0.62Kg |
| Packing |
20pcs/13.6Kg/0.72CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation |
| |
|
| OUTPUT |
|