| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
88¡«132 VAC/176¡«264VAC47¡«63 Hz£»Auto swiched 248¡«370VDC |
| AC Current |
5A/115 V 2.5A/ 230 V |
| Efficiency |
78%(SKS-240-5); 80%(SKS-240-7.5); 82%(SKS-240-12); 83%(SKS-240-15);
84%(SKS-240-24); 85%(SKS-240-30); 87%(SKS-240-48);
|
| Inrush Current |
Cold start 18A/115V36A/230V |
| Leakage Current |
£¼2mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
105%¡«135% |
| |
rotection type: shut down o/p voltage, recovers automatically after fault condition is removed |
| Over Voltage |
115%~135% |
| |
Protection type: hiccup mode, recovers automatically after fault condition is removed |
| Fan Control |
RT1¡Ý40¡æ FAN ON£¬¡Ü35¡æ FAN OFF£¬¡Ý70¡æ output shutdown |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£¬20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle£¬period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
UL1950,TUVEN60950(7.5V Design refer to UL1950) |
| EMC Standard |
EN55022,EN61000-3-2,-3,en61000-4-2,3,4,5,6,8,11;ENV50204 |
| |
|
| OTHERS |
|
| Weight |
1.2Kg |
| Packing |
12pcs/15.3Kgs/0.78CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|