| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
AC 170¡«264VAC 47¡«63 Hz£»DC 240¡«370VDC |
| AC Current |
0.45A/ 230V |
| Efficiency |
65%(HSM-15-5) ;68%(HSM-15-15);72%(HSM-15-24); |
| Inrush Current |
Cold start 36A/230VAC |
| Leakage Current |
< 1 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
110%¡«160% Constant current limiting, recovers automatically after fault condition is removed |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH(Refer to output load derating curve) |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz,2G 10min./1cycle,period for 60 min,each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P£º2KVAC I/P-FG£º1.5KVAC O/P-FG£º0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL1012 |
| EMC Standard |
EN55022 CLASSA |
| |
|
| OTHERS |
|
| Weight |
0.16Kg |
| Packing |
117pcs/18.8Kg/0.9CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.
Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì parallel capacitor. |
| |
3.
Tolerance: includes set up tolerance, line regulation and load regulation |
| |
|
| OUTPUT |
|