| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
180¡«260VAC 47¡«63 Hz£»selected by switch 260¡«370VDC |
| AC Current |
5.0A/ 230 VAC |
| Efficiency |
83%£¨HSCP-800-9); 84%£¨HSCP-800-12); 85%£¨HSCP-800-15);
86%£¨HSCP-800-18);
88%£¨HSCP-800-24); 88%£¨HSCP-800-36); 89%£¨HSCP-800-48); 90%£¨HSCP-800-60);
|
| Inrush Current |
60A/230V |
| Leakage Current |
3.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
105%¡«115% |
| |
Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover |
| Over Voltage |
110%~135% |
| |
Protection type: Shut down o/p voltage, re-power on to recover |
| Over Temp. |
TSW1£¨Powre transistor£©temp.>100 ¡æ, shut down o/p voltage. Temp. 100 ¡æ, O/I auto-recovery |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-20¡æ¡«+65¡æ£¬20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£¬10%¡«95 %RH |
| Vibration |
10¡«200Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to 60950,TUV EN60950 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11 |
| |
|
| OTHERS |
|
| Weight |
2.3Kg; |
| Packing |
8pcs/20kg/CARTON |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4.Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down |
| |
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|
| OUTPUT |
|