1200W Parallel (N+1) With PFC Function(HSCP-1K2 )  
Features:  
INPUT voltage range: AC180~260V
PF>0.98@230VAC
Protections: Short circuit/ Over load/Over voltage/ Over   temperature
Built-in remote ON-OFF control and remote sense function
  Power good signal
With parallel function (N+1)£©
Can adjust from 20%~100% output voltage by external
  control 1-5V
Forced air cooling by built-in DC fan
3 years warrantyDimensions: 290*120*132mm£¨L*W*H£©
 
Data

   Short Form Datasheet
  CE- Cerfiticate
 
SPECIFICATIONS  
   
INPUT  
Voltage Range 180¡«260VAC47¡«63 Hz£»selected by swith 260¡«370VDC
AC Current 10A/ 230 VAC
Efficiency 80%£¨HSCP-1K2-5);  82%£¨HSCP-1K2-9);84%£¨HSCP-1K2-12);  85%£¨HSCP-1K2-15); 86%£¨HSCP-1K2-18);  
89%£¨HSCP-1K2-24);89%£¨HSCP-1K2-36);90%£¨4HSCP-1K2-8); 90%£¨HSCP-1K2-60);
Inrush Current 60A/230V
Leakage Current 3.5 mA/240VAC
   
OUTPUT See Datasheet
   
PROTECTION  
Over Load 105%¡«140%
  Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover
Over Voltage 110%~135%
  Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. TSW1£¨Power transistor£©Temp.>100 ¡æ, shut down o/p voltage. Temp£¼100 ¡æ , O/I auto-recovery.
   
ENVIRONMENT  
Working Temp., Humidity -20¡æ¡«+65¡æ£¬20%¡«90 %RH
Storage Temp., Humidity -20¡æ¡«+85¡æ£¬10%¡«95 %RH
Vibration 10¡«200Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG :100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL60950,TUV EN60950
EMC Standard Design refer to EN55022,EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
   
OTHERS  
Weight 4.5Kg;
Packing 4pcs/19kg/CARTON
   
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
  2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì
   parallel capacitor.
  3.Tolerance: includes set up tolerance, line regulation and load regulation.
  4.Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
  5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
   be re-confirmed that it still meets EMC directives.
   
OUTPUT  
Model
HSCP-1K2
  5 9 12 15 18 24 36 48 60
DC Voltage 5V 9V 12V 15V 18V 24V 36V 48V 60V
Voltage Tolerance ¡À2.0% ¡À1.5% ¡À1.0% ¡À1.0% ¡À1.0% ¡À1.0% ¡À1.0% ¡À1.0% ¡À1.0%
Rated Current 200A 133A 133A 80A 66A 50A 33A 24A 20A
Current Range 0£­200A 0£­133A 0£­133A 0£­80A 0£­66A 0£­50A 0£­33A 0£­24A 0£­20A
Rated Power 1000W 1200W 1200W 1200W 1200W 1200W 1200W 1152W 1200W
Ripple & Noise 100mVp-p 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p 360mVp-p 480mVp-p 500mVp-p
DC Adjustment Range

Can adjust from 20%~100% output voltage by external control 1-5V

Setup,Rise,Hold Time 500ms, 50ms, 16ms at full load