600W Single Output Switching Power Supply With Parallel Function (HSCN-600)  
Features:  
 High reliability, low ripple
 Universal AC input/ full range
 Protections: Short circuit/ Over load/ Over voltage/ Over   temperature
 Built-in ON-OFF control and remote sense function
 With parallel function
 Can adjust from 20%~100% output voltage by external   control 1-5V
 Focred air cooling by built-in DC fan
 2 years warranty
 Dimensions: 291*132*68mm£¨L*W*H£©
 
Data

   Short Form Datasheet
  CE- Cerfiticate
 
SPECIFICATIONS  
   
INPUT  
Voltage Range 90¡«130VAC / 180¡«260 VAC47¡«63 Hz£»selected by switch 260¡«370VDC
AC Current 11 A/115 VAC 7.0A/ 230 VAC
Efficiency 77%(HSCN-600-5); 80%(HSCN-600-12); 81%(HSCN-600-15); 82%(HSCN-600-18); 85%(HSCN-600-24);  87%(HSCN-600-48); 
Inrush Current 60A/230V
Leakage Current 3.5 mA/240VAC
   
OUTPUT See Datasheet
   
PROTECTION  
Over Load 101~115%(HSCN-600-5); 110%¡«135%(HSCN-600-1); HSCN-600-15; (HSCN-600-18;HSCN-600-24; HSCN-600-48)
  Protection type: Current limiting, delay shut down o/p voltage, re-power on to recover
Over Voltage 110%~135%
  Protection type: Shut dwon o/p voltage, re-power on to recover
Over Temp. TSW1£¨Power transistor£©When temp. >100 ¡æ, shut down o/p voltage, re-power on to recover
   
   
ENVIRONMENT  
Working Temp., Humidity -10¡æ¡«+65¡æ£¬20%¡«90 %RH
Storage Temp., Humidity -20¡æ¡«+85¡æ£¬10%¡«95 %RH
Vibration 10¡«200Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P, I/P-FG:1500VAC
Isolation Resistance I/P-O/P, I/P-FG, 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL1950,CSA22.2,IEC60950
EMC Standard Design refer to FCC Part 15 Class A
   
OTHERS  
Weight 2.3Kg;
Packing 8pcs/24.0kg/CARTON
   
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
  2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
   parallel capacitor.
  3.Tolerance: includes set up tolerance, line regulation and load regulation
  4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
   be re-confirmed that it still meets EMC directives.
   
OUTPUT  
Model HSCN-600-5 HSCN-600-12 HSCN-600-15 HSCN-600-18 HSCN-600-24 HSCN-600-48
DC Voltage 5V 12V 15V 18V 24V 48V
Voltage Tolerance ¡À1.5% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1%
Rated Current 100A 50A 40A 33A 25A 12A
Current Range 0£­100A 0£­50A 0£­40A 0£­33A 0£­25A 0£­12A
Rated Power 500W 600W 600W 600W 600W 600W
Ripple & Noise 100mVp-p 120 mVp-p 150 mVp-p 180 mVp-p 240mVp-p 480mVp-p
DC Adjustment Range

Can adjust from 20%~100% output voltage by external control 1-5V

Setup,Rise,Hold Time 800ms, 50ms, 16ms at full load