500W With PFC and Parallel Function SMPS(HPSP-500)  
Features:  
 High efficiency, high reliability
 Universal AC input/ full range
 Built-in active PFC function, PF>0.95
 Protections: Short circuit/ Over load/ Over voltage/ Over    temperature
 Forced air cooling by built-in DC fan
 Current sharing up to 2000W(3+1)
 With power good and fail signal output
 Built-in remote ON-OFF control and remote sense function
 3 years warranty
 Dimensions: 278*127*63.5mm£¨L*W*H£©
 
Data

   Short Form Datasheet
  CE- Cerfiticate
 
SPECIFICATIONS  
   
INPUT  
Voltage Range 90¡«264 VAC47-63Hz£»127¡«370VDC
Power Factor 0.95/230VAC0.98/100VAC at full load
AC Current 7A/115 VAC3.5A/230VAC
Efficiency 76%(HPSP-500-5);      82%(HPSP-500-12);   82%(HPSP-500-13.5); 82%(HPSP-500-15);
84%(HPSP-500-24);    84%(HPSP-500-27);   86%(HPSP-500-48);
Inrush Current Cold start 20A/115VAC40A/230VAC
Leakage Current <1mA/240VAC
   
OUTPUT See Datasheet
   
PROTECTION  
Over Load 110%~125%
  Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 115%¡«135%
  Protection type: Shut down o/p voltage, re-power on to recover
Over Temp.

RTH2¡Ý95¡æ£¨Detect on heatsink of Q1,Q7 power transistor & L3 output choke

  Protection type: Shut down o/p voltage, re-power on to recover
   
ENVIRONMENT  
Working Temp., Humidity -10¡æ¡«+60¡æ£»20%¡«90 %RH
Storage Temp., Humidity -20¡æ¡«+85¡æ£»10%¡«95 %RH
Vibration 10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL1950,TUV EN60950
EMC Standard Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024
   
OTHERS  
Weight 2.6Kg
Packing 6pcs/15.7Kg/1.45 CUFT
   
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
  2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
   parallel capacitor.
  3.Tolerance: includes set up tolerance, line regulation and load regulation.
  4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
   be re-confirmed that it still meets EMC directives.
   
OUTPUT  
Model
HPSP-500
  5 12 13.5 15 24 27 48
DC Voltage 5V 12V 13.5V 15V 24V 27V 48V
Voltage Tolerance ¡À2% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1% ¡À1%
Rated Current 80A 41.5A 37A 33A 20.8A 18.5A 10.5A
Current Range 0£­80A 0£­41.5A 0£­37A 0£­33A 0£­20.8A 0£­18.5A 0£­10.5A
Rated Power 400W 498W 499.5W 495W 499.2W 499.5W 504W
Ripple & Noise 240mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 200mVp-p 300mVp-p
DC Adjustment Range -5%,+10% -17%,+10% ¡À11% -10%,+20% -17%,+10% ¡À11% -15%,+17%
Setup,Rise,Hold Time 1500ms,50ms,15ms at full load