| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
176¡«264 VAC47-63Hz£»248¡«370VDC |
| Power Factor |
PF>0.95/230VACat full load |
| AC Current |
10.5A/230 VAC |
| Efficiency |
77%£¨HPSP-1000-5); 84%£¨HPSP-1000-12);
84%£¨HPSP-1000-13.5);
84%£¨HPSP-1000-15);
85%£¨HPSP-1000-24); 85%£¨HPSP-1000-27); 86%£¨HPSP-1000-48);
|
| Inrush Current |
Cold start 100A/230VAC |
| Leakage Current |
<3.5mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
115%~140% |
| |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage |
115%¡«135% |
| |
Protection type: Shut down o/p voltage, re-power on to recover |
| Over Temp. |
95 (TSW1) Detect on the heatsink of PFC MOSFET 90 (TSW2) Detect the winding of output chok
|
| |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
| |
|
| FUNCTION |
|
| Remote ON-OFF Control (Optional) |
RC+/RC-£º0~0.8V POWER ON£¬4~10V POWER OFFsink current <30mA |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+65¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL1950,TUV EN60950 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
| |
|
| OTHERS |
|
| Weight |
7.4Kg |
| Packing |
2pcs/15.5Kg/1.28 CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4£®10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power. |
| |
5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|
| OUTPUT |
|