1000W Single Output with PFC Function SMPS (HPSP-1000)  
Features:  
 High efficiency, high reliability
 Universal AC input/ full range
 Built-in active PFC function, PF>0.95
 Protections: Short ciruit/ Over load /Over voltage/Over    temperature
 Built-in constant current limiting circuit
 Forced air cooling by built-in DC fan
 Current sharing up to 2 units or 2000W
 Built-in remote ON-OFF control and remote sense   function
 Built-in active current sharing and parallel function
 3 years warranty
 Dimensions: 278*129*127mm£¨ L*W*H£©
 
Data

   Short Form Datasheet
  CE- Cerfiticate
 
SPECIFICATIONS  
   
INPUT  
Voltage Range 90¡«264 VAC47-63Hz£»127¡«370VDC
Power Factor PF>0.95/230VAC  PF>0.95/115VAC at full load
AC Current 14A/115 VAC  7A/230VAC
Efficiency 77%£¨HPSP-1000-5);      84%£¨HPSP-1000-12);   84%£¨HPSP-1000-13.5); 84%£¨HPSP-1000-15);
86%£¨HPSP-1000-24);    86%£¨HPSP-1000-27);   86%£¨HPSP-1000-48);
Inrush Current Cold start 40A/115VAC70A/230VAC
Leakage Current <2mA/240VAC
   
OUTPUT See Datasheet
   
PROTECTION  
Over Load 115%~140%
  Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 115%¡«135%
  Protection type: Shut down o/p voltage, re-power on to recover
Over Temp.

95 (TSW1) Detect on the heatsink of PFC MOSFET 90 (TSW2) Detect the winding of output choke

  Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
   
ENVIRONMENT  
Working Temp., Humidity -10¡æ¡«+65¡æ£»20%¡«90 %RH
Storage Temp., Humidity -20¡æ¡«+85¡æ£»10%¡«95 %RH
Vibration 10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL1950,TUV EN60950
EMC Standard Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024
   
OTHERS  
Weight 5.2Kg
Packing 3pcs/16.3Kg/1.42 CUFT
   
NOTE 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
  2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
   parallel capacitor.
  3.Tolerance: includes set up tolerance, line regulation and load regulation.
  4.10% Duty cycle maximum within every 30 seconds(max.). Average output power should not exceed the rated power.
  5.The power supply is considered a component which will be installed into a final equipment. The final equipment must
   be re-confirmed that it still meets EMC directives.
   
OUTPUT  
Model
HPSP-1000
  5 12 13.5 15 24 27 48
DC Voltage 5V 12V 13.5V 15V 24V 27V 48V
Voltage Tolerance ¡À6.0% ¡À3.0% ¡À2.0% ¡À2.0% ¡À1.0% ¡À1.0% ¡À1.0%
Rated Current 145A 75A 67A 60A 37.6A 33.6A 19A
Current Range 0£­145A 0£­75A 0£­67A 0£­60A 0£­37.6A 0£­33.6A 0£­19A
Rated Power 725W 900W 904.5W 900W 902.4W 907.2W 912W
Peak Value Power 800W 1000W 1000W 1000W 1000W 1000W 1000W
Ripple & Noise 100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
DC Adjustment Range -5%,+10% -17%,+10% ¡À11% -10%,+20% -17%,+10% ¡À11% -15%,+17%
Setup,Rise,Hold Time 1.5s,50ms,15ms/230VAC1.5s,50ms,1.5ms/115VAC at full load