| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
85¡«264VAC47¡«63Hz ;120~370VDC |
| AC Current |
0.6A/115VAC0.4A/230VAC |
| Efficiency |
66%(HPS-25-3.3); 74%(HPS-25-5);76%(HPS-25-7.5); 78%(HPS-25-12);78%(HPS-25-13.5);
78%(HPS-25-15);79%(HPS-25-24);79%(HPS-25-27); 79%(HPS-25-48);
|
| Inrush Current |
Cold start 36A/230VAC |
| Leakage Current |
<0.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
>105%, Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage |
115%-135% Shut down o/p voltage, re-power on to recovery |
| Over Temp. |
U1¡Ý135¡æÊ±£¬Shut down o/p voltage, auto-recovery |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL60950-1, TUV EN60950-1 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5 |
| |
|
| OTHERS |
|
| Weight |
0.14Kg |
| Packing |
96pcs/15Kg/1.3CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|