| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
85¡«264VAC127~370VAC47¡«63Hz |
| AC Current |
0.65A/115VAC0.4A/230VAC |
| Efficiency |
71%(HPD-25A); 77%(HPD-25B); 73%(HPD-2505); 74%(HPD-2512); 75%(HPD-2515);
|
| Inrush Current |
Cold start 32A |
| Leakage Current |
<0.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
>105% |
| |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
| Over Voltage |
115%~135% |
| |
Protection type: Shut down o/p voltage, re-power on to recover |
| OVER TEMP. |
U1¡Ý135¡æ£¬shut down o/p voltage, recovers automatically after fault condition is removed |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL60950-1, TUV EN60950-1 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5 |
| |
|
| OTHERS |
|
| Weight |
0.15Kg |
| Packing |
96pcs/15.9Kg/1.3CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|