| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
85¡«264 VAC47¡«63 Hz£» selected by switch 120¡«370VDC |
| AC Current |
0.88 A/115 V 0.48A/ 230 V |
| Efficiency |
74%(HDR-30-5); 81%(HDR-30-12); 82%(HDR-30-15); 83%(HDR-30-24) |
| Inrush Current |
Cold start 15A/115V 30A/230V |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
105%¡«160% |
| |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage |
115%~135% |
| |
Protection type: Shut down o/p voltage, re-power on to recover |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVAC |
| Isolation Resistance |
I/P-O/P: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
| EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3
|
| |
|
| OTHERS |
|
| Weight |
0.27Kg |
| Packing |
48pcs/14Kg/1.02CUFT |
| |
|
| NOTE |
|
| 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì parallel capacitor. |
| 3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
| |
|
| OUTPUT |
|